Follow along with the video below to see how to install our site as a web app on your home screen.
Note: This feature may not be available in some browsers.
Normal
It's valid to test directly to the coil IF you have removed all wires from the coil and if you don't do it long - putting 12volts on a 6 volt coil directly for more than a few seconds can burnout the coil. Trying that test with wires connected at best tells you little of value and at worst burns out your Rita.