Normal
Be aware that Atlas/Dommie oil tanks have an inherent weakness at the point where the upper mounting flange (An "L" shaped tab at the top of the tank) is welded to the tank roof.The tab flexes with vibration and fatigues the tank metal until failure, resulting in a leak that is easily mistaken for a filler cap leak.PM me for a fix should you encounter this.Slick
Be aware that Atlas/Dommie oil tanks have an inherent weakness at the point where the upper mounting flange (An "L" shaped tab at the top of the tank) is welded to the tank roof.
The tab flexes with vibration and fatigues the tank metal until failure, resulting in a leak that is easily mistaken for a filler cap leak.
PM me for a fix should you encounter this.
Slick